EPS1

  • for Villa Elevator, Integration System of Elevator
  • Support the lift in 5HP-20HP
  • Manual Rescue Output: 60Vdc, 110Vdc, 220Vdc (option)

Model

EPS1.6K

EPS2K

EPS3K

Capacity

1600VA / 960W

2000VA / 1600W

3000VA / 2100W

AC Input

220Vac or 380Vac ± 25% Single Phase Input.  50/60Hz ± 10%

Charger Type

Controlled Rectifier CVCC

Charging Time

6 Hours for 90% of Full Battery Capacity

Inverter

Technology

Mosfet based PWM Wave

Output Voltage

220-240Vac or 380-415Vac Single Phase  50/60Hz ± 0.1Hz

Inverter Efficiency

85%

Overload

120% continuous, 125-150% repeat 6 times

Crest Factor

4:1

Power Factor

0.8

LED Indicator

AC normal, Rescue, Fail

Protection

Output Overload & Short circuit, DC Under & Over Voltage, Battery low

Dimension (L*W*D)

295*240*125mm